Philips HF-P 136TLD 1 x 36W Electronic ballast
- Philips HF-P 136TLD 1 x 36W Electronic ballast
- HF-P 118/136 TL-D III 220-240V 50/60 Hz
- Full Product Code: 872790091164000
- Order code: 913713031566
- Application Code
- III
- Type Version
- IDC
- Lamp Type
- TL-D
- Number of Lamps
- 1 piece/unit
- Number of Products on MCB (16A Type B) (Nom)
- 28
- Automatic Restart
- Yes
- Operating and Electrical
- Input Voltage
- 220 to 240 V
- Input Frequency
- 50 to 60 Hz
- Operating Frequency (Nom)
- 45 kHz
- Ignition Method
- Programmed Start
- Crestfactor (Max)
- 1.7
- Power Factor 100% Load (Nom)
- 0.99
- Ignition Time (Max)
- 0.9 s
- Mains Voltage Performance (AC)
- -8%-+6%
- Mains Voltage Safety (AC)
- -10%-+10%
- Earth Leakage Current (Nom)
- 0.5 mA
- Inrush Current Width
- 0.25 ms
- Constant Wattage Deviation
- -2%/+2%
- Ballast Factor (Nom)
- 1
- Power Losses (Nom)
- 2.5-4.1 W
- Inrush Current Peak (Max)
- 18 A
- Wiring
- Connector Type Input Terminals
- WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
- Cable Capacity Output Wires Mutual (Nom)
- 200 pF
- Connector Type Output Terminals
- WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
- Cable Length Hot Wiring
- 0.75 m
- Wire Striplength
- 8.0-9.0 mm
- Dual Fixture Master/Slave
- Not applicable [ Master/Slave oper. not applicable]
- Input Terminal Cross Section
- 0.50-1.00 mm²
- Output Terminal Cross Section
- 0.50-1.00 mm²
- Cable Capacity Output Wires to Earth (Nom)
- 200 pF
- System characteristics
- Rated Ballast-Lamp Power
- 36/18 W
- Rated Lamp Power on TL-D
- 36/18 W
- System Power on TL-D
- 35.2/19.1 W
- Lamp Power on TL-D
- 31.1/16.6 W
- Power Loss on TL-D
- 4.1/2.5 W
- Rated Lamp Power on PL-L
- 36 W
- System Power on PL-L
- 34.6 W
- Lamp Power on PL-L
- 30.7 W
- Power Loss on PL-L
- 3.9 W
- Temperature
- T-Ambient (Max)
- 60 °C
- T-Ambient (Min)
- -25 °C
- T-Storage (Max)
- 50 °C
- T-Storage (Min)
- -40 °C
- T-Case Lifetime (Nom)
- 80 °C
- T-Case Maximum (Max)
- 80 °C
- T-Ignition (Max)
- 60 °C
- T-Ignition (Min)
- -25 °C
- Mechanical and Housing
- Housing
- L 280x30x28
- Emergency Operation
- Nominal Light Output After 60 Seconds
- 100% of EBLF
- Battery Voltage Lamp Ignition
- 186-275 V
- Normal Operating Voltage (DC)
- 220-240 V
- Battery Voltage Lamp Operation
- 186-275
- Battery Voltage Guaranteed Operation
- 176-275 V
- Battery Voltage Guaranteed Ignition
- 186-275 V
- Emergency Ballast Lumen Factor (EBLF) (Nom)
- 0.7 %
- Nominal Light Output After 5 Seconds
- 50% of EBLF
- Approval and Application
- Energy Efficiency Index
- A2 BAT
- IP Classification
- IP 20 [ Ingress Protection 20]
- EMI 9 kHz … 30 MHz
- EN55015
- EMI 30 MHz … 1000 MHz
- EN55022 level B
- Safety Standard
- IEC 61347-2-3
- Performance Standard
- IEC 60929
- Quality Standard
- ISO 9000:2000
- Environmental Standard
- ISO 14001
- Harmonic Current Emission Standard
- IEC 61000-3-2
- EMC Immunity Standard
- IEC 61547
- Vibration Standard
- IEC68-2-6 F c
- Bumps Standard
- IEC 68-2-29 Eb
- Humidity Standard
- EN 61347-2-3 clause 11
- Approval Marks
- CE marking
- ENEC certificate
- VDE-EMV certificate
- Temperature Marking
- Yes
- Emergency Standard
- IEC 60598-2-22
- Hum And Noise Level
- < 30 dB(A)
- Product Data
- Full product code
- 872790091164000
- Order product name
- HF-P 118/136 TL-D III 220-240V 50/60 Hz
- EAN/UPC – Product
- 8711500999641
- Order code
- 913713031566
- Numerator – Quantity Per Pack
- 1
- Numerator – Packs per outer box
- 12
- Material Nr. (12NC)
- 913713031566
- Net Weight (Piece)
- 0.202 kg